SL-DH-300-121 300W12V Inverter DC to AC,Provide a variety of voltage and power options
Features:
High conversion efficiency and quick start;
Strong load adaptability and stability;
Provide over-current and short-circuit protection to avoid electrical damage;
Built-in fuse, safe and reliable;
Provide low voltage protection; provide overload protection;
Quiet operation, solid and practical appearance, easy to carry;
Main functions and protection:
1. Under-voltage protection (protect the life of the battery): When the battery voltage drops to the set under-voltage point of the machine, the buzzer will alarm and it will automatically stop after one minute.
2. Over-voltage protection: The over-voltage system is automatically closed.
3. Overload protection: Overload delay protection.
4. Overheating protection: when 40℃, the machine will automatically start the fan to dissipate heat; when it exceeds 65℃, it will alarm for one minute and stop; when it exceeds 70℃, it will shut down immediately.
5. Charging protection: constant current and constant voltage charging.
Model | SL-DH-300-121 |
SL-DH-300-241 |
SL-DH-300-481 |
SL-DH-300-122 |
SL-DH-300-242 |
SL-DH-300-482 |
Output Power |
300W |
300W |
300W |
300W |
300W |
300W |
Peak power |
600W |
600W |
600W |
600W |
600W |
600W |
Input voltage |
12V |
24V |
48V |
12V |
24V |
48V |
Output voltage |
110VAC |
220VAC |
||||
No-load current |
0.5A |
0.25A |
0.12A |
0.5A |
0.25A |
0.12A |
Output frequency |
50Hz/60HZ |
|||||
Output waveform | Pure sine wave | |||||
Waveform distortion |
THD<2%(Linear load) |
|||||
Output efficiency |
>85% |
>88% |
>90% |
>85% |
>88% |
>90% |
Input voltage range |
10.5-15V |
21-30V |
42-60V |
10.5-15V |
21-30V |
42-60V |
Undervoltage alarm |
10.5±0.3V |
21±0.3V |
42±0.3V |
10.5±0.3V |
21±0.3V |
42±0.3V |
Undervoltage protection |
10±0.3V |
20±0.3V |
40±0.3V |
10±0.3V |
20±0.3V |
40±0.3V |
Overvoltage protection |
15.5±0.5V |
31±1V |
62±2V |
15.5±0.5V |
31±1V |
62±2V |
Undervoltage recovery |
12±0.5V |
24±1V |
48±2V |
12±0.5V |
24±1V |
48±2V |
Overvoltage recovery |
14.8V |
29.5V |
59V |
14.8V |
29.5V |
59V |
Protective function | Undervoltage/overvoltage: LED red light on, automatic recovery | |||||
Overload: LED red light on, automatic recovery | ||||||
Over temperature: LED red light on, automatic recovery | ||||||
Short circuit: LED red light on, automatic recovery | ||||||
Input reverse connection: blown fuse | ||||||
Working temperature |
0℃-40℃ |
|||||
Storage temperature |
-30℃-70℃ |
|||||
Size |
320*240*80mm |
|||||
weight |
1.8kg |